3,065 research outputs found

    Superconducting screening on different length scales in high-quality bulk MgB2 superconductor

    Get PDF
    High quality bulk MgB2 exhibit a structure of voids and agglomeration of crystals on different length-scales. Because of this, the superconducting currents percolate between the voids in the ensuing structure. Magnetic measurements reveal that the superconducting currents circulate on at least three different length-scales, of ~1 micrometre, ~10 micrometre and whole of the sample (~millimetre). Each of these screenings contributes to the measured irreversible magnetic moment (Dm). The analysis of the field dependence of Dm for samples of subsequently decreasing size showed that the critical current obtained using the simple critical state model is erroneous. This leads to the artefact of the sample size-dependent critical current and irreversibility field. Our data analysis enables the separation of the contribution of each of the screening currents to Dm. The field dependence of each of the currents follows a stretched exponential form. The currents flowing around whole of the sample give a dominant contribution to Dm in the intermediate fields (1T < H < 4T at 20K) and they can be used to obtain the value of Jc from critical state model, which corresponds to the transport Jc

    On finite--temperature and --density radiative corrections to the neutrino effective potential in the early Universe

    Full text link
    Finite-temperature and -density radiative corrections to the neutrino effective potential in the otherwise CP-symmetric early Universe are considered in the real-time approach of Thermal Field Theory. A consistent perturbation theory endowed with the hard thermal loop resummation techniques developed by Braaten and Pisarski is applied. Special attention is focused on the question whether such corrections can generate any nonzero contribution to the CP-symmetric part of the neutrino potential, if the contact approximation for the W-propagator is used.Comment: 11 pages, revtex styl

    Precision Drift Chambers for the Atlas Muon Spectrometer

    Full text link
    ATLAS is a detector under construction to explore the physics at the Large Hadron Collider at CERN. It has a muon spectrometer with an excellent momentum resolution of 3-10%, provided by three layers of precision monitored-drift-tube chambers in a toroidal magnetic field. A single drift tube measures a track point with a mean resolution close to 100 micron, even at the expected high neutron and gamma background rates. The tubes are positioned within the chamber with an accuracy of 20 microns, achieved by elaborate construction and assembly monitoring procedures.Comment: 3 pages, 2 eps figures, Proceedings for poster at Physics in Collisions Conference (PIC03), Zeuthen, Germany, June 2003. FRAP1

    Large-Scale Production of Monitored Drift Tube Chambers for the ATLAS Muon Spectrometer

    Full text link
    Precision drift tube chambers with a sense wire positioning accuracy of better than 20 microns are under construction for the ATLAS muon spectrometer. 70% of the 88 large chambers for the outermost layer of the central part of the spectrometer have been assembled. Measurements during chamber construction of the positions of the sense wires and of the sensors for the optical alignment monitoring system demonstrate that the requirements for the mechanical precision of the chambers are fulfilled

    Comparative study of in situ and ex situ MgB2 films deposited by pulsed laser deposition

    Full text link
    Two types of MgB2 films were prepared by pulsed laser deposition (PLD) with in situ and ex situ annealing processes respectively. Significant differences in properties between the two types of films were found. The ex situ MgB2 film has a Tc of 38.1K, while the in situ film has a depressed Tc of 34.5K. The resistivity at 40K for the in situ film is larger than that of the ex situ film by a factor of 6. The residual resistivity ratios (RRR) are 1.1 and 2.1 for the in situ and ex situ films respectively. The Jc-H curves of the in situ film show a much weaker field dependence than those of the ex situ film, attributable to stronger flux pinning in the in situ film. The small-grain feature and high oxygen level may be critical for the significant improvement of Jc in the in situ annealed MgB2 film.Comment: 6 pages, 6 figure

    ATLAS monitored drift tube chambers for super-LHC

    Get PDF
    After the high-luminosity upgrade of the Large Hadron Collider (LHC) at CERN, the ATLAS muon spectrometer is expected to work at 10 times increased background rates of gammas and neutrons. This is challenging as the momentum resolution of the spectrometer is expected to be 10 %. This requires a single tube resolution of the muon drift tubes of 80 mum. At background rates around 1000 Hz/cm2 space charge effects will lead in the slow and non-linear AR:CO2 = 93:7 gas mixture to a degradation of the drift-tube spatial resolution. This was studied before experimentally for gammas and low energetic neutrons. Almost no information exists for fast neutrons. Therefore, we organized our studies under the following aspects: - We investigated the influence of 11 MeV neutrons on the position resolution of ATLAS MDT chambers. At flux densities between 4 and 16 kHz/cm2, almost no influence on the position resolution was found, it degrades by only 10 mum at a detection efficiency of only 4*10-4. - We investigated inert gas mixtures on fastness and linearity of their position-drifttime (r-t) relation. At a reduction of the maximum drift time by a factor of 2, the use of the present hardware and electronics might be possible. For our experimental studies we used our Munich cosmic ray facility. Two gas mixtures show almost identical position resolution as the standard gas. - For spectrometer regions of highest background rates we contributed to the investigation of newly developed 15 mm drift tubes. Position resolutions have been measured as a function of gamma background rates between 0 and 1400 Hz/cm2. - Garfield simulations have been performed to simulate space charge effects due to gamma irradiation. Results will be presented for the standard geometry as well as for the new 15 mm drift tubes.Comment: 3 pages, 7 figures, conferenc
    • …
    corecore